Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM02153
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/30/2006 | FRAMING | Approved | IVRS - Inspection :* | |
03/27/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE BLOCK 2ND FLOOR BEDROOM WEST AND NORTH SIDE WINDOW 2) BLOCK VENTS 2ND FLOOR 3) STRAP NORTH EAST WALL NOT NAILED OFF 4) ANCHOR BOLTS LOOSE AT DINING ROOM LEDGER |
|
03/24/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OFF HOLDOWNS EAST WALL 2) NUTS LOOSE ON WALL ANCHOR BOLTS THROUGHOUT WALL 3) NAIL PROTECT ELECTRIC THROUGHOUT HOUSE 4) MISSING SMOKIES 2ND FLOOR BEDROOMS 5) BLOCK MECHANICAL AT FURNACE ROOM AND 2ND FLOOR 6) FIRE BLOCK 2ND FLOOR N/W BEDROOM AT WINDOW, ALSO NOOK AT HALLWAY |
|
03/23/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NO PLANS/PERMIT AVAILABLE |