Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05CM02139
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/04/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* CORRECTION MADE |
|
07/29/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) SEE NOTE #1 FROM 7/26/05. PROVIDE CORRECT CONDENSATE DRAIN TERMINATION AT SODA SERVICE STATION. HAVE SODE DISPENSING EQUIPMENT INSTALLKED CORRECTLY |
|
07/26/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) INSTALL ANSUL VALVES PER PLAN OR PROVIDE CITY APPROVED REVISED PLAN 2) WHERE UNIONS ARE NEEDED LEFT-RIGHT NIPPLES AND COUPLINGS SHALL BE USED EVEN AT ANSUL VALVE LOCATIONS 3) PROVIDE LISTING PLATES FOR ALL APPLIANCES AND CORRECT GAS APPLIANCE CONNECTORS PER PLAN PAGE P-1 NOTE (1) RETEST GAS SYSTEM 4) INDIRECT DRAINS TO BE SEPERATE FOR ICE MACHINE DRAINAGE 5) PROVIDE CORRECT BACKFLOW PROTECTION FOR H20 TO CARBONATOR AND DELIVERY GUN, AND ICE MACHINE WITH CERTIFICATIONS 6) SUPPORT PIPING DROPS FOR GAS AT G-9 THRU G-13 |