Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/07/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GARAGE P.3 NOT NAILED PER PLAN 2) FIRE STOPS AND BLOCKS NOT IN 3) 1" CLEARANCE REQUIRED TO COMBUSTABLE MATERIAL AT 2ND FLOOR 4) FIRE BLOCK S.E. BEDROOM 5) PLUMBING OUT OF WALL LAUNDRY 6) WIRES BELOW CEILING FRAME |
|
| 09/02/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GARAGE P3 SHEAR WALL REQUIES ENDS AND EDGES NAILED AT 3" O.C. 2) W/H T AND P LINE MUST BE 6" ABOVE SIDEWALK 3) PEX MUST BE 6" FROM "B" VENT 4) SECURE WIRES WITHIN 8" OF ELECTRIC BOXES 5) FIRE STOP GARAGE AT 2ND FLR 6) FIRE STOP W/H "B" VENT 2ND FLOOR 7) W/H "B" VENT REQUIRES 1" TO COMBUSTABLE MATERIAL TWO PLACES 8) FIRE STOP S.E. BEDROOM 9) FIRE STOP LAUNDRY 10) PLUMBING OUT OF WALL LAUNDRY 11) SECOND FLOOR P-1 SHEAR WALL BOTTOM PLATE NOT NAILED PER PLAN 12) FIRE STOP FLOOR PENETRATIONS 13) NO GAS TEST 14) FIRE STOP N.W. DUCT |
|
| 08/30/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) PEX MUST BE 12" FROM CAN LIGHTS 2) HOLD DOWNS MISSING - SEE PLAN 3) GARAGE P.3 SHEAR REQUIRES ANCHOR BOLTS AT 16" OC 4) GARAGE P.3 REQUIRES ENDS AND EDGES NAILED AT 3" OC 5) DWV LEAK ABOVE LIVING ROOM 6) NAIL PROTECT PLUMBING 7) PLUMBING OUT OF WALL STOPPED INSP TOO MANY ITEMS |