Permit: T05CM02134

Parcel: 140378410


Addresses:

6750 S AQUILINE DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/07/2005 FRAMING Approved IVRS - Inspection :*
09/06/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE P.3 NOT NAILED PER PLAN
2) FIRE STOPS AND BLOCKS NOT IN
3) 1" CLEARANCE REQUIRED TO COMBUSTABLE MATERIAL AT 2ND FLOOR
4) FIRE BLOCK S.E. BEDROOM
5) PLUMBING OUT OF WALL LAUNDRY
6) WIRES BELOW CEILING FRAME
09/02/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE P3 SHEAR WALL REQUIES ENDS AND EDGES NAILED AT 3" O.C.
2) W/H T AND P LINE MUST BE 6" ABOVE SIDEWALK
3) PEX MUST BE 6" FROM "B" VENT
4) SECURE WIRES WITHIN 8" OF ELECTRIC BOXES
5) FIRE STOP GARAGE AT 2ND FLR
6) FIRE STOP W/H "B" VENT 2ND FLOOR
7) W/H "B" VENT REQUIRES 1" TO COMBUSTABLE MATERIAL TWO PLACES
8) FIRE STOP S.E. BEDROOM
9) FIRE STOP LAUNDRY
10) PLUMBING OUT OF WALL LAUNDRY
11) SECOND FLOOR P-1 SHEAR WALL BOTTOM PLATE NOT NAILED PER PLAN
12) FIRE STOP FLOOR PENETRATIONS
13) NO GAS TEST
14) FIRE STOP N.W. DUCT
08/30/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) PEX MUST BE 12" FROM CAN LIGHTS
2) HOLD DOWNS MISSING - SEE PLAN
3) GARAGE P.3 SHEAR REQUIRES ANCHOR BOLTS AT 16" OC
4) GARAGE P.3 REQUIRES ENDS AND EDGES NAILED AT 3" OC
5) DWV LEAK ABOVE LIVING ROOM
6) NAIL PROTECT PLUMBING
7) PLUMBING OUT OF WALL
STOPPED INSP TOO MANY ITEMS