Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/22/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/21/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 11/17/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REVERSE PITCH ON WATER HEATER B-VENT REQUIRED 1/4" PER FOOT RISE MINIMUM 2) 1" CLEARANCE REQUIRED TO COMBUSTIBLE MATERIAL AT WATER HEATER B-VENT 3) WATER HEATER B-VENT AND PLUMBING CHASE NOT FIRE STOPPED |
|
| 11/14/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) T & P LINE MUST EXHAUST BETWEEN 6" + 18" 2) GARAGE SHEAR P-3 REQUIRES 12 A35 CLIPS 3) RED HEAD ANCHOR BOLTS LOOSE 4) STRAP/CLIP POSTS 5) NAIL BEDROOM 3 ? 6) NAIL PEX POWDER ROOM 7) WATER HEATER "B" VENT INSTALLED UP SIDE DOWN |