Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/19/2005 | FRAMING | Cancelled | CANCELLED PER SUPERINTENDENT TIM OF K.B. HOMES #907-6040 | |
| 12/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MAXIMUM ALLOWED STAIR RISE 7 3/4"-PRESENTLY 8" 2) MAXIMUM ALLOWED DIFFERENCE IN STAIR RISE IS 3/8"-PRESENTLY 1 1/8" 7/8", 8 1/4" TO 7 3/8" 3) TOP STAIR RISE NOT LEVEL 8 1/4" TO 7 3/4" 4) W/H B-VENT NOT PROPERLY FIRE STOPPED DO NOT USE INSULATION 5) REPAIR STUCCO LATH AT DRYER |
|
| 12/13/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LIVING ROOM ELECTRIC CONVENIENCE OUTLET CANNOT BE ON KITCHEN COUNTER CIRCUIT 2) MAXIMUM ALLOWED STAIR RISE 7 8/4"-PRESENTLY 8" 3) FIRESTOP WATER HEATER VENT 2ND FLOOR 4) NO GAS BOND 5) NAIL PROTECT WIRES AT 2/SD2 |
|
| 12/12/2005 | FRAMING | Cancelled | CANCELLED PER TIM OF K.B. HOMES #907-6040 | |
| 12/08/2005 | FRAMING | Cancelled | CANCELLED PER JOE SOLIS OF K.B. HOMES #907--6049 | |
| 12/08/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |