Permit: T05CM02127

Parcel: 140376930


Addresses:

7031 S HARRIER LP

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/20/2005 FRAMING Approved IVRS - Inspection :*
12/19/2005 FRAMING Cancelled CANCELLED PER SUPERINTENDENT TIM OF K.B. HOMES #907-6040
12/15/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MAXIMUM ALLOWED STAIR RISE 7 3/4"-PRESENTLY 8"
2) MAXIMUM ALLOWED DIFFERENCE IN STAIR RISE IS 3/8"-PRESENTLY 1 1/8" 7/8", 8 1/4" TO 7 3/8"
3) TOP STAIR RISE NOT LEVEL 8 1/4" TO 7 3/4"
4) W/H B-VENT NOT PROPERLY FIRE STOPPED DO NOT USE INSULATION
5) REPAIR STUCCO LATH AT DRYER
12/13/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LIVING ROOM ELECTRIC CONVENIENCE OUTLET CANNOT BE ON KITCHEN COUNTER CIRCUIT
2) MAXIMUM ALLOWED STAIR RISE 7 8/4"-PRESENTLY 8"
3) FIRESTOP WATER HEATER VENT 2ND FLOOR
4) NO GAS BOND
5) NAIL PROTECT WIRES AT 2/SD2
12/12/2005 FRAMING Cancelled CANCELLED PER TIM OF K.B. HOMES #907-6040
12/08/2005 FRAMING Cancelled CANCELLED PER JOE SOLIS OF K.B. HOMES #907--6049
12/08/2005 FRAMING Not ready for Inspection IVRS - Inspection :*