Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/16/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/06/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL H2.5 EVERY JOIST PER DETAIL 6/5
2) OSB MUST REACH TOP PLATES PER DETAIL 1/5
3) BIRD BOARDS SHORT MUST REACH OSB 8D AT 6" ON CENTER PER DETAIL 6/5
4) COMPLY WITH DETAIL 5/5 REAR ADDITION
5) PROVIDE ACCESS TO ROOF
6) STOPPED INSPECTION