Permit: T05CM02120

Parcel: 140376100


Addresses:

6877 S GOSHAWK DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/10/2005 FRAMING Approved IVRS - Inspection :*
10/07/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER JOE
10/06/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OK TO INSULATE
2) FIRE STOP W/H "B" CHASE AND 12" DUCT CHASE
2) INTERIOR BEARING WALLS REQUIRE TWO A.B. MINIMUM
10/03/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) RED HEAD ANCHOR BOLTS LOOSE
2) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE
3) PLUMBING OUT OF WALL BY WATER HEATER
4) GARAGE P-2 SHEAR REQUIRES ANCHOR BOLTS AT 16" ON CENTER
5) REAR P-3 SHEARWALL REQUIRES ANCHOR BOLTS AT 16" ON CENTER
6) STOPPED INSPECTION-TO MANY ITEMS
09/29/2005 FRAMING Not ready for Inspection IVRS - Inspection :*