Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/10/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/07/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JOE |
|
| 10/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OK TO INSULATE 2) FIRE STOP W/H "B" CHASE AND 12" DUCT CHASE 2) INTERIOR BEARING WALLS REQUIRE TWO A.B. MINIMUM |
|
| 10/03/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) RED HEAD ANCHOR BOLTS LOOSE 2) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE 3) PLUMBING OUT OF WALL BY WATER HEATER 4) GARAGE P-2 SHEAR REQUIRES ANCHOR BOLTS AT 16" ON CENTER 5) REAR P-3 SHEARWALL REQUIRES ANCHOR BOLTS AT 16" ON CENTER 6) STOPPED INSPECTION-TO MANY ITEMS |
|
| 09/29/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |