Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/09/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio YOU MUST PAY A REINSPECTION FEE PRIOR TO NEXT INSPECTION 1) ROUGH PLUMBING DAMAGE REPAIRED BELOW SLAB SURFACE AND REPAIR COVERED WITHOUT INSPECTION. EXPOSE REPAIR AND TEST 2) P-3 WINDOW EDGES NOT NAILED AT 3" ON CENTER 3) PROVIDE NAIL PROTECTION FOR PLUMBING WITHIN 1 1/4" OF PLATE SURFACE |
|
| 09/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REAR P-3 SHEARWALL NOT NAILED AT 3" ON CENTER AT ENDS AND EDGES 2) ROUGH PLUMBING DAMAGED BY NAILS-FIX NOW 3) PROVIDE NAIL PROTECTION FOR PLUMBING WITHIN 1 1/4" OF STUD SURFACE |
|
| 08/31/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO LOT # OR ADDRESS POSTED 2) HEADERS MUST BEAR ON TRIMMERS 3) STUD MISSING BY ENTRY MUST BE 16" OC 4) REAR P.3 SHEAR WALL NOT NAILED AT 3" OC 5) ROUGH PLUMBING DAMAGED BY NAILS 6) PROVIDE NAIL PROTECTION FOR ALL PLUMBING WITHIN 1 1/4" OF STUD SURFACE 7) C.S. 20 STRAPS SOUTH WALL MUST BE TREAT? |