Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/21/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 11/14/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE 4" CLEARANCE BETWEEN SOIL/GRAVEL AND WEEP SCREED AT ENTRY 2) STAIR HAND RIALS MUST RUN PARALLEL TO STAIR RISERS AND BE 36 PLUS/MINUS 2" IN ELEVATION |
|
| 11/07/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE UV PROTECTION FOR PVC PIPE 2) PROVIDE 4" CLEARANCE BETWEEN SOIL AND STUCCO WEEP SCREED 3) PROVIDE 5 PERCENT SLOPE 5 FEET FROM POST TENSION SLAB AT REAR 4) HANDRAIL AT WINDER ONLY 31" MUST BE 36" PLUS/MINUS 2" 5) NO STUCCO CERTIFICATE 6) NO DISHWASHER DRAIN |