Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/20/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE PARAPETS |
|
| 04/11/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) EXCEPT GARAGE PARAPETS |
|
| 04/10/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/28/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
| 03/07/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) REVISE PLAN FOR SCISSOR TRUSS OR BUILD TO PLAN DETAILS MUST MATCH |
|
| 03/06/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE TRUSS CALC'S 2) INSTALL H2.5 PER DETAIL 1/S3 3) HOLDOWNS GARAGE ENTRY WALLS 8A 3) STRAP PORCH BEAMS 4) INSTALL A-35 PER DETAL 1/S3 GARAGE LEDGERS 5) NAIL OSB JOINT ? AT LIVING ROOM SOUTH WALL 6) INSTALL 2 X 6 BLOCKING PER DETAIL 1/S3 NOTE (4) 7) REAR PORCH NOT PER PLAN DETAIL 6/S3 8) DETAILS ON S.3 DO NOT MATCH ROOF FRAMING S.2 |