Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM02114

Parcel: 12205030A


Addresses:

4420 E EDISON ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/20/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/17/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE PARAPETS
04/11/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) EXCEPT GARAGE PARAPETS
04/10/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/28/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
03/07/2006 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) REVISE PLAN FOR SCISSOR TRUSS OR BUILD TO PLAN DETAILS MUST MATCH
03/06/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE TRUSS CALC'S
2) INSTALL H2.5 PER DETAIL 1/S3
3) HOLDOWNS GARAGE ENTRY WALLS 8A
3) STRAP PORCH BEAMS
4) INSTALL A-35 PER DETAL 1/S3 GARAGE LEDGERS
5) NAIL OSB JOINT ? AT LIVING ROOM SOUTH WALL
6) INSTALL 2 X 6 BLOCKING PER DETAIL 1/S3 NOTE (4)
7) REAR PORCH NOT PER PLAN DETAIL 6/S3
8) DETAILS ON S.3 DO NOT MATCH ROOF FRAMING S.2