Inspection History Details
Permit: T05CM02104
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/15/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FIRE BLOCK MISSING AT MASTER TOILET DROPPED CEILING 2) SEE #3, 4, 6, 7 3) DWV'S OK, RETEST WATER LINES 4) OK TO INSULATE 3050 - NOT REQUIRED ALL ELECTRIC |
|
| 09/13/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HDS IN GARAGE SCREWS NOT IN 2) NO TEST ON WATER LINES 3) PROVIDE 12" CLEARANCE FOR PEX AT CAN LIGHTS 4) FIRE BLOCK RIGHT SIDE OF FRONT DOOR 5) HOLD DOWN UNDER STAIRS NOT NAILED AND NUT MISSING 6) FIRE BLOCK MECH. CHASE 7) FIRE BLOCK CONCEALED SPACE BEHIND SHOWER 8) DWVS OK 9) HD AT POWEDER ROOM NOT NAILED AND LAUNDRY |