Permit: T05CM02103


Addresses:

970 W CALLE CARASOL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/30/2005 FRAMING Approved IVRS - Inspection :*
09/29/2005 FRAMING Partial Approval IVRS - Inspection :*
1) SEE NOTE NUMBER ONE INSPECTION DATED 9/26/05
09/26/2005 FRAMING Partial Approval IVRS - Inspection :*
1) PROVIDE 12" CLEARANCE FOR WATER LINES FROM CAN LIGHTS
2) LPI'S AT KITCHEN DAMAGED
3) DWV'S OK
4) OK TO INSULATE
5) NO GAS-ALL ELECTRIC. ITEM 03050 NOT APPLICABLE
09/23/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
09/22/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL PENETRATIONS FROM 1ST TO 2ND FLOOR
2) LPI'S DAMAGED IN GARAGE
3) 2X6 STUD IN GARAGE OVERNOTCHED
4) FIRE BLOCK DROP AT HALL
5) CPI'S IN B/R DAMAGED
6) STOPPED INSP
09/15/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STUCCO MESH NOT COMPLETE
2) 2ND FLOOR SHEAR MISSING AND HOLDDOWNS
CK ALL SHEAR FOR PROPER INSTALLATION