Permit: T05CM02076

Parcel: 118043670


Addresses:

1517 W BEANTREE LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM02076

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/09/2005 FRAMING Approved IVRS - Inspection :*
10/04/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LATH NOT STAPLED 16" ON CENTER, SEAL ALL PENETRATIONS
2) SEE INSPECTION DATED 9/30/05 ITEMS 1, 2, 3, 4 AND 7
09/30/2005 FRAMING Partial Approval IVRS - Inspection :*
09/23/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE ROMEX WITHIN 8" FROM BOX AT KITCHEN
2) NO TEST ON DWV'S OR GAS LINE
3) FIREBLOCK CHASE AT KITCHEN
4) BLOCK MECHANICAL AT POWDER ROOM
5) 3" CLEANOUT MISSING AT POWDER ROOM
6) DETAIL 4SD2 DOES NOT MATCH FRAMING
7) SEAL PENETRATIONS FROM 1ST TO 2ND FLOOR
8) NAIL PROTECT ELECTRIC AT TOP OF STAIRS
9) EXHAUST FAN MISSING AT LAUNDRY
10) REMOVE SCREEN FROM DRYER VENT
11) NAIL PROTECT VTR N/W CORNER
12) SEAL MECH CHASE