Permit: T05CM02067

Parcel: 118043710


Addresses:

1493 W BEANTREE LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM02067

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/11/2006 FRAMING Approved IVRS - Inspection :*
11/17/2005 FRAMING Partial Approval IVRS - Inspection :*
1) TRUSS REPAIR PER DETAIL, NEED CITY OF TUCSON APPROVAL STAMP
11/03/2005 FRAMING Partial Approval IVRS - Inspection :*
1) PROVIDE APPROVED REPAIR CITY OF TUCSON FOR F1 FLOOR TRUSS REPAIRS
2) STRONG BACKS NOT INSTALLED-SEE NOTES
10/04/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE APPROVED TRUSS CALC'S
2) OK TO INSULATE-DO NOT INSTALL SHEETROCK
09/30/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT PLUMBING AT KITCHEN
2) PANCAKE BOXES IN MASTER BATH NOT GROUNDED
09/23/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DWV'S LEAK AT 3" LINE AT LAUNDRY
2) NAIL PROTECT PLUMBING AT KITCHEN
3) PROVIDE SHEAR AND OVER BORED 2 X 6 STUDS BEARING
4) PROVIDE APPROVED TRUSS REPAIR AT GLB AREA
5) WATER LINES NEED 12" CLEARANCE FROM CAN LIGHTS
6) STOPPED INSPECTION-HOUSE NOT WALKED BY SUPER
09/15/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
09/15/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LATH, SEAL ALL PENETRATIONS
2) SLOPING NAILER MISSING AT GARAGE
3) WRONG HANGER USED AT GLB IN GARAGE
4) COMPLY WITH DETAIL 3B-SD-2
5) LADDER TRUSS FL1 DAMAGED
6) D12 WRONG HANGERS USED
7) FIRE BLOCK CHASE IN GARAGE
STOPPED INSPECTION