Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM02067
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/11/2006 | FRAMING | Approved | IVRS - Inspection :* | |
11/17/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) TRUSS REPAIR PER DETAIL, NEED CITY OF TUCSON APPROVAL STAMP |
|
11/03/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PROVIDE APPROVED REPAIR CITY OF TUCSON FOR F1 FLOOR TRUSS REPAIRS 2) STRONG BACKS NOT INSTALLED-SEE NOTES |
|
10/04/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE APPROVED TRUSS CALC'S 2) OK TO INSULATE-DO NOT INSTALL SHEETROCK |
|
09/30/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT PLUMBING AT KITCHEN 2) PANCAKE BOXES IN MASTER BATH NOT GROUNDED |
|
09/23/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DWV'S LEAK AT 3" LINE AT LAUNDRY 2) NAIL PROTECT PLUMBING AT KITCHEN 3) PROVIDE SHEAR AND OVER BORED 2 X 6 STUDS BEARING 4) PROVIDE APPROVED TRUSS REPAIR AT GLB AREA 5) WATER LINES NEED 12" CLEARANCE FROM CAN LIGHTS 6) STOPPED INSPECTION-HOUSE NOT WALKED BY SUPER |
|
09/15/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
09/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LATH, SEAL ALL PENETRATIONS 2) SLOPING NAILER MISSING AT GARAGE 3) WRONG HANGER USED AT GLB IN GARAGE 4) COMPLY WITH DETAIL 3B-SD-2 5) LADDER TRUSS FL1 DAMAGED 6) D12 WRONG HANGERS USED 7) FIRE BLOCK CHASE IN GARAGE STOPPED INSPECTION |