Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM02064
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/23/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
09/07/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOLD DOWN NOT NAILED TO GARAGE WALL 2) REPLACE ALL DAMAGED CLIPS 3) WIND BRACE WEST SIDE OF GARAGE TO SHORT 4) LTHL HANGER IN GARAGE MISSING NAILS 5) DECK NOT FRAMED PER PLAN 6) OVER SPANS 2ND FLOOR 7) PROVIDE 1/8" GAP AT ROOF SHEETHING |