Permit: T05CM02063

Parcel: 118043720


Addresses:

1487 W BEANTREE LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM02063

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/02/2005 FRAMING Approved IVRS - Inspection :*
09/30/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT ABS AT MASTER BATH
2) ROOF PATIO NOT DRIED IN (DECK)
3) S.G.D. MISSING
4) SUPPORT 90 DEGREE ABS
5) NAIL PROTECT ELECTRIC IN KITCHEN
09/23/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL ALL LATH PENETRATIONS
2) PROVIDE APPROVED ENGINEER REPQIR FOR CABLE AT NORTH WEST CORNER OF GARAGE AND N/E SIDE
3) LATH STAPLES MISSING THROUGHOUT, BACK PATIO AREA NOT DONE
4) S.G.D. MISSING
5) SMOKE DETECTOR MUST HAVE 36" IN CLEARANCE FROM REGISTER
6) LEAK AT KITCHEN WATER LINES
7) NEED NEW TRUSS CALC'S
8) DWV'S OK
9) HANGERS MISSING NAILS
10) FRESH AIR AT MASTER DAMAGED
09/15/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TIGHTEN ANCHOR BOLTS THROUGHOUT
2) NAIL PROTECTION THROUGHOUT
3) CLAMP GAS LINE IN LAUNDRY
4) BLOCK HVAC ABOVE STAIRS
5) SUPPORT VENT 90 DEGRESS TO ROOF ABOVE TUB
6) SUPPORT HDR IN NW BEDROOM
7) SHIM UNDER TRUSSES @ INTERIOR BEARING
8) FIRESTOP HVAC BOOT TO ATTIC @ M. BATH
9) PLN NOT HOLDING PER LEAKS UNDER 2ND FLOOR TUBS