Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/14/2008 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 02/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OUT AT 6' NORTH SITE WALL |
|
| 01/09/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 12" CMU WALL @ GRID LINE "L" FROM #6 TO #7 TOP OUT @ 24'4" |
|
| 01/08/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 12" CMU WALL AT GRID LINE "L" FROM #6 TO #7 @ 16FT TO 20 FT |
|
| 01/04/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. 12" CMU WALL AT GRID LINE "L" FROM #6 TO #7 @ 16 FT 2. 3 - 8" CMU WALL FROM GRID 7 TO 8 @ D, F & J - TOP OUT |
|
| 01/03/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. 8" CMU WALLS BETWEEN GRID 7 & 8 @ D.F & J TO 5'4" (1ST LIFT) 2. 8" CMU WALL AT GRID #7 FROM C TO L TOP OUT |
|
| 01/02/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 12/29/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) SITE RAINED OUT |
|
| 12/28/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 8" CMU WALLS D, F & J FROM GRID #7 & #8 STEMS ONLY 2) 12" CMU WALL #6-ATOC TOP OUT 3) 12" CMU WALL A-6 TO 7 TOP OUT 4) 12" CMU WALL #7-A TO D TOP OUT |
|
| 12/27/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. 12" CMU WALL #6 -- A TO C @ 20FT 2. 12" CMU WALL A -- 6 TO 7 @ 20FT 3. 12" CMU WALL #7 -- A TO L @ 20 FT. |
|
| 12/26/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 12/22/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* OK TO GROUT 12" CMU WALL @ GRID #7 A TO L 4TH LIFT 12FT TO 16FT |
|
| 12/21/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. 12" CMU WALL AT SERVICE SECTION (WALLS @ 6, M & 1.8 TO 24'8") 2. 12" CMU WALL AT 6, A & 7 TO 16 FT ON WEST SIDE 3. 12" CMU WALL AT 7-E TO L TO 12 FOOT |
|
| 12/20/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* OK TO GROUT 1. 12" CMU WALL #6-A TO C @ 12 FT 2. 12" CMU WALL A-6 TO 7 @ 12 FT 3. 8" CMU WALL #6-C TO L @ 11FT 1INCH 4. 8" CMU WALL #7-B PLUS TO E @ 11FT 1 INCH |
|
| 12/19/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. 12" CMU WALL #6 FROM L TO M TO 20 FEET OK TO GROUT 2. 12" CMU WALL M FROM 6 TO 1.8 TO 20 FEET OK TO GROUT 3. 12" CMU WALL #1.8 FROM L TO M TO 20 FEET OK TO GROUT 4. 12" CMU WALL L FROM 1.8 TO 2 TO 20 FEET OK TO GROUT |
|
| 12/18/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 12/15/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SECOND LIFT TO 8 FOOT 1. 8" CMU WALL #7 B TO L & 12" CMU WALL #7 FROM A TO B 2. 12" CMU WALL #A 6 TO 7 & 12" CMU WALL #6 A TO C 3. 8" CMU WALL #6 C TO L |
|
| 12/13/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 12/12/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. B.5 TO G.5 LINE 7 CMU WALL TO 5FT. 4 IN. MUST USE CLEANOUT HOLES. 2. WALL 6 FROM L TO M - WALL M FROM 1.8 TO 6 & WALL 1.8 FROM L TO M. |
|
| 12/11/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 12/07/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 12/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WALL M -6 TO 1.8 12" CMU TO 12 FT WALL 6 - L TO M 12" CMU TO 12 FT WALL 1.8 - L TO M 12" CMU TO 12 FT |
|
| 12/05/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. 8" CMU WALL 8-B TO L AT TOP OUT TO 12 FT. & WALL B 7 TO 8 TOP OUT TO 12 FT. 2. 12" CMU WALL A-6 TO 7 AT 1ST LIFT TO 4FT 3. 8" CMU WALL L-7 TO 8 AT 2ND LIFT TO 8FT & 12" CMU WALL L-6 TO 7 2ND LIFT TO 8 FT. |
|
| 12/01/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 11/29/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* OK TO GROUT 1. BACK EXTERIOR SERVICE DEPT. CMU WALL 1ST LIFT TO 5FT. 2. EAST EXTERIOR GUM WALL AT SERVICE RECEPT. CENTER 1ST LIFT TO 5FT. GRID LINE M 1.8 TO 6 |