Permit: T05CM02054

Parcel: 116122680


Addresses:

1306 W SONORA ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/23/2006 FRAMING Approved IVRS - Inspection :*
11/17/2005 FRAMING Partial Approval IVRS - Inspection :*
1) COMPLETE ALL TRADES THEN RECALL ALL INCLUDING FRAMING
11/15/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
11/08/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MUST INSTALL H2.5 HURRICANE TIES TO 2 X 8 PLATE BOLTED TO MASONRY (FROM TRUSSES)
2) ROOF SHEATHING TO SPAN 3 RAFTERS (2 RAFTER SPACES)
3) NEED LADDER TO INSPECT ROOF
4) STOPPED INSPECTION