Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/02/2005 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* ALL FTGS INTERIOR AND EXTERIOR OK TO POUR |
|
| 08/31/2005 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* EXTERIOR FTGS OK TO POUR - INTERIOR FTG NOT READY 4) MUST RELOCATE H2O LINE AT INTERMEDIATE INSPECTION |
|
| 08/04/2005 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1 BLOCKS SUPPORTING REBAR CAN BE NO LARGER THAN 3"X3" 2 MAINTAIN MIN 3" REBAR TO DIRT CLEARANCE 3 PLAN CALLS FOR FOOTING CONT AT REAR PORCH ENTRY 4 MUST RELOCATE H20 LINE OR REPLACE WITH APPRV MATERIALS UNDER SLAB |