Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM02036
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/12/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
10/10/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) SUPER DID NOT INSPECT |
|
10/06/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) CHECK ALL NAILS NOT REPLACED IN GIRDER HANGERS 2) 2 X 6 PLATE WASN'T USED EAST ABOVE STAIRS-ADD TRUSS CLIPS, 2 NAILS IN EACH H-1 ONLY |
|
08/16/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO COVER ROOF/WALLS 2) CHECK AT INTERMEDIATE INSP. NEED 16D'S IN 2ND FLOOR ROOF HIP HANGER AND GIRDER HANGER 3) FLIP FRONT DOOR HEADER AROUND 2-2 X 6'S REQUIRED |
|
08/15/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) FRONT SHEAR AND CLIP REAR PORCH 2) HAND NAIL PORCH LEDGER |