Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/20/2005 FRAMING Approved IVRS - Inspection :*
06/16/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ELECTRIC SUB-PANEL REQUIRES AN ISOLATED NEUTRAL BAR
2) JUNCTION BOXES CANNOT BE INCLOSED IN WALL CAVITY. INSTALL BOX EXTENSIONS
3) ELECTRIC SERVICE PANEL RISER SECURED WITH LOCK RINGS. YOU MUST INSTALL A BONDING BUSHING/CLAMP ON RISER TO PANEL