Permit: T05CM02020

Parcel: 140383810

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/04/2005 FRAMING Approved IVRS - Inspection :*
10/03/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TIGHTEN HOLDOWN NUTS
09/29/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE SHEARWALL 6 NOT NAILED AT 4" ON CENTER AT EDGES
2) HOLDOWNS NUTS LOOSE
3) REPAIR ROOF DAMAGE BY RANGE HOOD AND INSTALL JACK
09/26/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LOOSE NUTS AT HOLDOWNS
2) LOOSE WIRES IN KITCHEN AREA
3) NO WATER TEST ON TOP OUT
4) PEX WATER LINES SHALL BE 12" FROM LIGHT CANISTERS
5) STOPPED INSPECTION-CANCELLED BY SUPER