Date Description Inspector Results Comments
06/24/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/22/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) H.D. INTERIOR SHEAR
2) BELLY BAND NOT NAILED
3) BLOCK AND NAIL ROOF, OSB RUN PARALELL OF TRUSSES
4) SHIM 3 PTS
06/17/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) ROOF OSB TURNED PARALELL WITH TRUSSES, BLK AND NAIL
2) TRIPLE HANGERS AT HIPS WRONG SIZE NAILS
3) NAIL ALL BELLY BANDS
4) BRING PT. LOADING DOWN TO CONCRETE FROM ROOF (LOAD)
5) CLIP ALL SHEAR TRANSFER