Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/21/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/15/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) MISSING NAILING GARAGE ROOF, MARKED IN BALCK
2) USE 16D'S IN HANGER
3) BELLY BAN NOT NAILED TO 2ND FLOOR
4) ATTACH REAR COLUMN TO FOUNDATION
5) HANGER HOLDS 1695 POUNDS CALLS FOR (16'S NAILS). NAILS INSTALLED ARE 10D GOOD FOR 64 DEGREE OF 1695 POUNDS ACTUAL LOAD ON HANGER IS 1255 POUNDS