Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM01986

Parcel: 141017520


Addresses:

5920 S COURTLAND DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM01986

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/21/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/15/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) MISSING NAILING GARAGE ROOF, MARKED IN BALCK
2) USE 16D'S IN HANGER
3) BELLY BAN NOT NAILED TO 2ND FLOOR
4) ATTACH REAR COLUMN TO FOUNDATION
5) HANGER HOLDS 1695 POUNDS CALLS FOR (16'S NAILS). NAILS INSTALLED ARE 10D GOOD FOR 64 DEGREE OF 1695 POUNDS ACTUAL LOAD ON HANGER IS 1255 POUNDS