Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM01985
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/20/2005 | FRAMING | Approved | IVRS - Inspection :* | |
09/19/2005 | FRAMING | Partial Approval | IVRS - Inspection :* H.D. BOLTS/PLATE BOLTS |
|
09/16/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BOT. PLATE ANCHOR GARAGE AT JOINT 2) DBL STUDS GARAGE GIRDER 3) MOVE PEX FROM LIGHT CANS 12" CLR. 4) USE CORRECT HANGER AT 2ND FLR GIRDER 6) SAFETY GLASS WINDOWS STAIRS 7) A.C. LINES 2ND FLR BEHIND SHOWER, DUG INTO METAL STRAP 8) STAPLE IN RIGHT SIDE OF 2ND FLR LAV ARM 9) #3, #4, SHEAR WALLS 1ST FLR #3 GETS PINS A 6" O.C. #4 GETS BOLT 1/2" 0 AT 32 BOTH WALLS MISSING BOLTING AT H.D'S 10) LATH NOT COMPLETE |