Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/04/2005 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* | |
| 09/28/2005 | PLUMBING - YARD WTR LINE/TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING VENT 2ND FLOOR SHOWER, 90 DEGREE ONLY ON TRAP ARM USE 2/45 DEGREES 2) MISSING RETRO H.D. LIVING ROOM 3) #3 SHEAR 1ST FLOOR HILTI PINS AT 6" ON CENTER 4) CLEAN UP 2ND FLOOR MIDDLE BATH PIPING-SANTEE NOT LYE ON IT'S BAY 5) NAIL OFF ALL HORIZONTAL VERT SHEAR 6) NEED SAFETY GLASS TOP OF STAIR 7) RAFTER TIES, TIE EACH END OF TRUSS SAME TRUSS 8) LATH DAMAGED 9) CAULK ALL PENETRATIONS AND FINISH PARAPET 10) PLUMBING YARD WATER LINE COVERED WITHOUT INSPECTION |
|
| 06/22/2005 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* 1) NOT INSTALLED |
|
| 06/08/2005 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* |