Permit: T05CM01976

Parcel: 118081610


Addresses:

905 W CALLE CARASOL

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/15/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/21/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OVERSPANS WEST WALL
2) NAIL PROTECT ELECTRIC FROM OUTSIDE SOUTH WEST CORNER
3) HOLDOWNS REAR OF HOUSE NOT NAILED TO 2 KING STUDS
4) WRONG NAILS USED FOR HANGERS AT BACK PATIO
5) NAIL PROTECT ELECTRIC AT KITCHEN WALL
6) NAIL PROTECT ELECTRIC FROM OUTSIDE THROUGHOUT
7) HOLDOWN EAST WALL NOT NAILED TO 2 KING STUDS
07/11/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DBL TOP PLATE NOT STAGGERED WEST WALL
2) STRAP WALL AT 2 X 6 TO 2 X4 TRANSITION
3) OVERSPANS THROUGHOUT
4) HOLDOWNS REAR OF HOUSE NOT NAILED TO TWO KING STUDS
5) NO TRUSS CALC'S
6) STOPPED INSPECTION-TO MANY ITEMS