Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO DRY IN HOUSE 2) TWO WEST HOLDOWNS WRONG LOCATIONS 2) UFER GROUND WAS NOT INSPECTED BY CITY OF TUCSON-INSTALL 2 GROUND RODS |
|
| 10/04/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 2, 3 AND 4 OF 10/3 INSPECTION NOT DONE 2) NEXT FAILURE WILL REFEE |
|
| 10/03/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) R1 SHEARWALL NOT NAILED TO SOLID BLOCKING UNDER WINDOW 2) TWO HOLDOWNS WRONG LOCATION AT REAR OF HOUSE G-2 SHEAR 3) PORCH COLUMN REQUIRES TWO ANCHOR BOLTS PER PLATE 4) ROOF OSB PANEL ENDS AND EDGES MUST BE NAILED AT 6" ON CENTER OR STAPLED AT 4" ON CENTER. SOME PANELS NOT NAILED |