Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/19/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) LEAK AT HALL BATH REDUCER |
|
| 09/16/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* PER RON |
|
| 09/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) P-2 SHEAR NOT NAILED AT 4" O.C. 2) BLOCK OUT NOT COMPLETE 3) WET FLOORS/PLUMBING PLEASE DRY OUT 4) NAIL TRUSS CLIPS 5) LADDER BACK MISSING G-3 SHEAR WALL 6) TIGHTEN RED HEA OK 7) DRAFT STOP "B" VENT W/HI 8) ANCHOR 2ND FLOOR 9) NAIL SHEAR WALL BOTTOM PLATE 10) FIRE BLOCK THROUGHOUT 11) CHASE DUCT 12) NO 2ND FLOOR DWV WATER TEST 13) 3 CAR G AND B REQUIRES 4-2X6 POSTS |