| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/16/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/09/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CONNECT EXHAUST FANS 2) FINISH LATH 3) NAIL ALL RAFTERS TO PERPENDICULAR TRUSSES 4) BANG PLATE H20 SERVICE THRU-OUT 5) WILL NEED FLOOR SINK & TRAP PRIMER FOR H20 HTR T & P 6) SECURE POCKET DOORS 7) VENT TOILET WEST WALL MOVE CLOSET BEND 8) NEED SAFETY GLASS AT TUB 9) 2" VENT ROOF PENETRATIONS WEST LAV 10) FIRE STOP AT TOP OF CHASE 11) FINISH CONDENSATE DRAIN EAST UNIT 12) SECURE KITCHEN EXHAUST HOSE BIB 13) SECURE ALL PEX LINES 14) 12" PEX TO CANS 15) RE-PLUMB FIXTURE AT LAUNDRY 16) NEED LARGE HANGER AT BAY WINDOW AREA 17) HANGER LOAD AT B-2 TRUSS 1104 LBS 18) INSTALL RAT RUNS 19) HEARTH SAFETY STRIP 20) NEED 16D COMMON NAILS IN G1TV5.511 HANGER 21) BEFORE FINAL HAVE PLAN CHANGED, FOR FURNACE MOVED TO ATTIC 22) NEED DWV TEST AND POTABLE H20 PRESSURE ON |
|
| 01/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
| 01/10/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) REPLACE DAMAGED ROOF ? DE-LAMINATING PLY 2) FINISH EXT. SHEATHING 3) NEED TRUSS DRAWINGS 4) DETAIL 13/9 NAIL AND INSTALL BLOCKS BETWEEN TRUSSES NAIL ROOF 5) REAR ENTRY MISSED SOME BOLTING AT BOTTOM PLATES 6) AT 24" FROM DOORS FINISH INSTALLATION/SAFETY GLASS REQUIRED 7) INSPECTION IS FROM BLDG DRAIN TO SEPTIC |