Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/06/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/08/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) #5 FROM PREVIOUS INSP 2) OK TO INSULATE |
|
| 08/05/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SUPPORT GAS AND A/C IN GARAGE CEILING 2) BANG PLATE CONDENSATE 3) CREATE CLEARANCE TO WATER HEATER FLUE-1ST AND 2ND FLOOR AND FIREBLOCK 4) NO WATER IN DWV IN LAUNDRY-OK 2ND FLOOR 5) 2-3" ABS PENETRATIONS OF TOP PLATES IN 1ST FLOOR S.E. BED 6) BLOCK HALL BATH DUCT BOOT 2ND FLOOR 7) FIRE BLOCK GARAGE CEILING AT A/C PENETRATION 8) NOT DONE FOR WALK DECK FLOOR |