Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM01936
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/11/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/07/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIREBLOCK AT GARAGE SOFFIT 2) BLOCK TUB WALLS 3) BLOCK REGISTERS 3-SIDES 4) FIREBLOCK GARAGE BATH DROP 5) FIREBLOCK AT KITCHEN DROP/UPSTAIRS MASTER CLOSET MECHANICAL DUCT CHASE 6) FASTEN 6" ON CENTER AT TOP PLATES WEST WALL, ALL PORCHES AND EYEBROWS 7) NAIL PROTECT HOME RUNS TOP PLATE 8) INSTALL HOLDOWNS GARAGE WALLS SW6 AND SW5 9) GARAGE SW5 OSB BOTH SIDES BLOCKED 10) LAUNDRY SW3 0SB BLOCKED BOTH SIDES PROVIDE CONTINOUS TIE IN TO TJI'S 11) FIREBLOCK STAIRWELL BOTH SIDES/INSTALL GUARD RAIL BLOCKING |
|
| 10/05/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED |
|
| 10/03/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE STUCCO LATHE PRIOR TO INSPECTION |
|
| 09/28/2005 | FRAMING | Cancelled | IVRS - RI canceled |