Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM01936

Parcel: 11105121B


Addresses:

3226 E PRESIDIO RD


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM01936

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/11/2005 FRAMING Approved IVRS - Inspection :*
10/07/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIREBLOCK AT GARAGE SOFFIT
2) BLOCK TUB WALLS
3) BLOCK REGISTERS 3-SIDES
4) FIREBLOCK GARAGE BATH DROP
5) FIREBLOCK AT KITCHEN DROP/UPSTAIRS MASTER CLOSET MECHANICAL DUCT CHASE
6) FASTEN 6" ON CENTER AT TOP PLATES WEST WALL, ALL PORCHES AND EYEBROWS
7) NAIL PROTECT HOME RUNS TOP PLATE
8) INSTALL HOLDOWNS GARAGE WALLS SW6 AND SW5
9) GARAGE SW5 OSB BOTH SIDES BLOCKED
10) LAUNDRY SW3 0SB BLOCKED BOTH SIDES PROVIDE CONTINOUS TIE IN TO TJI'S
11) FIREBLOCK STAIRWELL BOTH SIDES/INSTALL GUARD RAIL BLOCKING
10/05/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED
10/03/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE STUCCO LATHE PRIOR TO INSPECTION
09/28/2005 FRAMING Cancelled IVRS - RI canceled