Permit: T05CM01933

Parcel: 136234700


Addresses:

3645 S YUKON PL

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
06/17/2005 BUILDING - FINAL Approved IVRS - Inspection :*
06/16/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PLEASE LEAVE MESSAGE WITH LOCK BOX CODE WHEN RECALLING
06/14/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SMOKE DETECTORS NOT OPERABLE
2) HOT WATER HEATER TPR DRAIN PIPE CANNOT BE FLEX-MUST BE HARD PIPED
3) TPR DRAIN LINE MUST HAVE POSITIVE PITCH (LIKE ANY DRAIN) PRESENTLY, IT IS BACK PITCHED