Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM01906

Parcel: 136287950


Addresses:

7363 E POINCIANA PL


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM01906

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/05/2005 FRAMING Approved IVRS - Inspection :*
08/02/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED RED HEAD ON W. GARAGE WALL AND AT MASTER TOILET
2) NEED TPR DRAIN LINE
3) NEED FHA STRAP ON MASTER LAV. VENT
4) SHIM SAG OVER PATIO DOOR
5) SECURE WALL AT STOVE VENT
6) ADD 3RD 2 X 4 UNDER WEST GIRDER TRUSS
7) BANG PLATE WIRES AT W. WALL OF S.W. BED
8) SECURE PEX IN N.W. RED
9) NEED WATER AND DWV
10) CAULK PATIO LIGHT, WEST AND EAST FASCIA, ENTRY GIRDER
11) FINISH MESH AT MASTER BATH