Permit: T05CM01899

Parcel: 11205283F

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
07/11/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :* 1) AT INTERCEPTOR INTERMINGLING OF MATERIAL TYPES IS NOT PERMITTED. REPLACE PVC WITH ABS 2) TRANSITION CEMENT IS LIMITED TO ONE CONNECTION WHERE BLDG DRAIN MEETS BLDG SEWER. PVC REPLACED WITH ABS. GREASE INTERCEPTOR OK TO COVER.
07/07/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) ABS DWV S.S. TO TWO WAY CLEANOUT OK. WATER TEST OK TO 10 FT
2) GREASE WASTE TO INSIDE BLDG WALL-OK. OK TO COVER INSIDE ONLY
3) AT GREASE INTERCEPTOR: CHANGE OF DIRECTION TO BE MADE WITH THE USE OF APPROVED FITTING
4) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP
5) VERTICAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP
6) NO VENT ON INTERCEPTOR
07/06/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :* THIS ADDRESS HAS MULTIPLE UNITS WITH TENANT IMPROVEMENTS WITHOUT THE SUITE NUMBER, i AM UNABLE TO MAKE THIS INSPECTION.