Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL RED HEADS AT FRONT OF GARAGE 2) BLOCK OFF COMBUSTION AND RELIEF VENTS 3) NEED H2.5S AT TOP OF SHEAR PER DT1-10 4) BAND PLATE LAUNDRY VENT ABS AND FRIDGE PEX AND OUTLET WIRE AT MASTER BATH/BED DOOR 5) REPAIR KIT STOVE WALL FIREBLOCKING AND MASTER CLOSET 6) SHIM HEADERS WHERE NEEDED 7) WIRE MASTER SINK LIGHT 8) SEAL FIREBLOCKING IN MASTER TUB CHASE 9) MOVE PEX FROM FURN PLATFORM ACCESS NOTE: LATHE NOT DONE AT SOUTH WALL AND PATIO AREAS |
|
| 09/14/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |