Permit: T05CM01779

Parcel: 141174940

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM01779

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/23/2005 FRAMING Approved IVRS - Inspection :*
09/21/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BANG PLATES - NW BEDROOM/GARAGE WALL TOP PLATE L.R. S.E. WALL TOP PLATE
09/20/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE NAIL PROTECTION OVER WIRES WHERE BORED HOLE IS WITHIN 1/4" OF EDGE OF STUD. TWO PLACES MARKED WITH BLACK X
09/19/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLETE STUCCO MESH
2) NAIL PROTECTION
3) PROTECT HOME RUNS LINES AT GANG PLATE ON TRUSS
09/16/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLETE LATH ON FRONT COLUMN
2) TIGHTEN ANCHOR BOLTS THROUGHOUT
3) SECURE B-VENT TO OBTAIN 1" CLEARANCE TO COMBUSTIBLES
4) PROTECT HOME RUN LINES AT TRUSS GANG PLATE
5) NAIL PROTECTION THROUGHOUT
6) PROVIDE DWV TEST
7) QUAD SWITCH BOX IN MASTER BATH MUST BE SECURED ON BOTH SIDES
8) AB MISSING IN SOUTH FAMILY ROOM WALL
9) FIREBLOCK WEST L.R. WALL
10) STOPPED INSPECTION