Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/23/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/20/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) DBL TOP PLATE AT GARAGE NOTCHED MORE THAN 25 PERCENT |
|
| 06/16/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO TEST ON GAS LINES 2) DBL TOP PLATE AT GARAGE NOTCHED MORE THAN 25 PERCENT 3) 2" DIRTY ARMS NOT ALLOWED AT LAVS REPAIR AND RETEST VENTS |
|
| 06/16/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) BLOCK BETWEEN COMB AND RELIEF 2) STAPLE MESH 6" ON CENTER TOP AT REAR PORCH |
|
| 06/13/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL AROUND OUTLET REAR OK HOUSE, BATH ROOM WINDOW, BOTTOM OF PANEL RISER, AROUND COACH LIGHTS 2) NAIL PROTECT DRYER VENT 3) PROVIDE APPROVED REPAIR AT GARAGE SHEAR TRANSFER WALL 4) HOLDOWN MISSING BOLT 5) GAS TEST FAILED 6) FIRE BLOCK KITCHEN DROP 7) ANCHOR BOLTS MISSING AT KITCHEN WALL 8) STOPPED INSPECTION |