Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/09/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/08/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JERRY |
|
| 08/05/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) WILL APPROVE WHEN 3035 COMPLETED 2) PLUMBER WORKING ON RELOCATING VENT PIPE 3) COMPLETE-H20 TEST AND RECALL |
|
| 07/28/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. TWO ANCHOR BOLTS REQUIRED EACH SILL PLATE 2. NO DWV WATER TEST 3. PEX WITHIN 12" OF CAN LIGHTS 4. NAIL PROTECT PLUMBING 5. WIRE EXHAUST FAN 6. PROVIDE 1/2" CLEARANCE AT NON BEARING WALLS TO TRUSS. 7. 10 FOOT SEPARATION REQUIRED BETWEEN SEWER VENTS AND AIR INTAKE. |