Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/12/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/14/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE ENGINEER OF RECORD EVALUATION OF 5/8" EXPANSION BOLTS AT 1 1/2" TO SLAB EDGE |
|
| 07/13/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING LT STRAP AT N.W. CORNER 2) NOTE: IT IS UNUSUAL TO USE WEDGE ANCHORS AT EDGE OF SLAB. PLEASE GET LETTER FROM ENGINEER ALLOWING THIS (SW7) 3) SW7 CALLS FOR 3" NAILING AT EDGES, THIS NORMALLY REQUIRES 3" NOMINAL LUMBER AT EDGES, PLEASE CLARIFY WITH ENGINEER |
|
| 07/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NO CHANGE FROM 7/5/05 INSPECTION |
|
| 07/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) PORCH COLUMNS NOT CLIPPED/ANCHORED 2) SHEARWALL 7 REQUIRES 5/8" ANCHOR BOLTS AT 24" ON CENTER 3) OK TO DRY IN ALL BUT COLUMNS ON FRONT AND BACK PORCH |