Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM01739

Parcel: 140383030

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/12/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/14/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE ENGINEER OF RECORD EVALUATION OF 5/8" EXPANSION BOLTS AT 1 1/2" TO SLAB EDGE
07/13/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING LT STRAP AT N.W. CORNER
2) NOTE: IT IS UNUSUAL TO USE WEDGE ANCHORS AT EDGE OF SLAB. PLEASE GET LETTER FROM ENGINEER ALLOWING THIS (SW7)
3) SW7 CALLS FOR 3" NAILING AT EDGES, THIS NORMALLY REQUIRES 3" NOMINAL LUMBER AT EDGES, PLEASE CLARIFY WITH ENGINEER
07/08/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NO CHANGE FROM 7/5/05 INSPECTION
07/05/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) PORCH COLUMNS NOT CLIPPED/ANCHORED
2) SHEARWALL 7 REQUIRES 5/8" ANCHOR BOLTS AT 24" ON CENTER
3) OK TO DRY IN ALL BUT COLUMNS ON FRONT AND BACK PORCH