Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOLDOWN MISSING REAR S.W. 2) NAILING NOT PER SCHEDULE S.W. 3) NAILS MISSING GARAGE TRUSS S.W. TRANSFER THRU OSB (ROOF SHEETHING) INTO TOP CHORD OF TRUSS |