Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM01703

Parcel: 116170120

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/15/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1. CORRECTIONS MADE OK
2. OK TO COVER ALL AREAS
08/11/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) PROVIDE INSPECTION HISTORY FOR YARD WATER PIPING OR EXPOSE ALL OF THE PIPING
2) SEE NOTE #3 FROM 08/08/05-CHANGE QUARTER BEND ON TRAP ARMS TO A SWEEP-RETEST
08/09/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) STILL NO TEST ON THE ABS
2) NO YARD WATER PIPING EXPOSED FOR INSPECTION
08/08/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) UNABLE TO LOCATE PLAN OR PERMIT
2) NO TEST ON ABS
3) HORIZONTAL AND HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP