Permit: T05CM01698

Parcel: 12209003A


Addresses:

3923 E PIMA ST


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T05CM01698

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/02/2005 MECHANICAL - FINAL Approved IVRS - Inspection :*
1) OK FOR FINAL C OF O
09/01/2005 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE MINIMUM 1" CLEARANCE FROM COMBUSTIBLES WHERE WATER HEATER VENT PENETRATES THE ROOF. STRAIGHTEN VENT PIPE, EXTEND 1 SEWER VENT 2' ABOVE EVAP COOLER. PROVIDE STAINLESS STEEL ON BOTH SIDES OF THE HOOD TO COVER THE SHEET ROCK SEE SECTION 507.9 2000 IMC. PROVIDE A GREASE CUP ON EXHAUST FAN. FIRE WRAP IS OK. OK FOR CEILING TILES EXCEPT AROUND WATER HEATER VENT