Permit: T05CM01698

Parcel: 12209003A


Addresses:

3923 E PIMA ST


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T05CM01698

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
07/08/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :* 1) DWV WATER TEST IS OK. 2) ALL CORRECTIONS HAVE BEEN MADE. 3) OK TO BACKFILL TRENCH.
07/07/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) CANNOT REDUCE THE TRAP ARM FOR P-5. 2) RE TEST THE SYSTEM
07/06/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) P TRAP FOR P-5 REQUIRES A 2" TRAP. OR PROVIDE A FLOOR SINK WITH A 3" OUTLET. ONLY ONE PIPE SIZE LARGER THAN THE OUTLET OF FIXTURE ALLOWED FOR TRAP SIZE. 2) REMOVE FERNCO COUPLING. 3) RE TEST THE SYSTEM.