Permit: T05CM01695

Parcel: 137294660

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/02/2005 FRAMING Approved IVRS - Inspection :*
10/31/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
10/25/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) UFER CUT
2) FIRE BLOCK DROP AT WATER HEATER
3) REPLACE ALL OVER NOTCHED BEARING STUDS
4) SHIM HEADERS WHERE NEEDED
5) NAIL PROTECT CONDENSATE LINE AT DEN
6) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR
7) STRAP MISSING AT KITCHEN WALL TO GLB CONNECTION
8) STOPPED INSPECTION-TO MANY ITEMS
9) SUPER NEEDS TO WALK HOUSE