Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NEED CONTINOUS BEARING AT REAR SCISSOR TRUSS. SHIM AT WEB MEMBERS (STRUCTUAL) 2) MISSED NAILING ROOK AT VERT WALL HOUSE TO GARAGE 3) TIE COLUMN STUDS TO PLATES 4) MISSED SHEAR CONNECTIONS PANELS TO DRAG TRUSS 10/DT1 5) CHECK ALL HORIZONTAL 6) NAIL 2 X 10 TO TRUSS PER 10/DT1 AND NAIL ROOF DRAG WITH 8D'S 6" ON CENTER |
|
| 06/06/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED RAT RUNS PER PLAN 2) BROKEN TRUSS "B" AT ENTRY 3) CLIPS AT FRONT COLUMN BOTTOM PLATE TO STUD 4) NAIL PERIMETER AT FRONT GABLE TO GARAGE |