Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T05CM01670
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/15/2005 | ROOF NAILING | Approved | IVRS - Inspection :* | |
06/10/2005 | ROOF NAILING | Partial Approval | IVRS - Inspection :* 1) MAIN HOUSE OK 2) PORCH NOT READY |
|
06/07/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALLED TRUSSES DO NOT MATCH TRUSS PLAN 2) 10/DT1 DRAG BLOCK NOT NAILED AT 6" ON CENTER 3) 6/DT1 HINGE BRACES INSTALLED BACKWARDS AT FRONT OF HOUSE 4) HEADERS MUST BEAR ON TRIMMERS 5) 3 PT BEARING TRUSSES MUST BEAR ON BEARING WALLS 6) STRAP NON OVER LAPPING DBL TOP PLATE OR CABIN TIE 7) 6/DT1 KNEE BRACES MUST BE NAILED THRU ROOF SHEATHING PER PLAN |