Permit: T05CM01666

Parcel: 114480890

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/11/2005 FRAMING Approved IVRS - Inspection :*
08/10/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE COMBUSTIBLES FROM FLUE AT ROOF
2) NEED POST UNDER S. END OF GIRDER TRUSS AND XFER LOAD TO SLAB
3) BLOCK VENT 90 DEGREE OVER MASTER TUB
4) SHIM HEADERS WHERE NEEDED
5) REPAIR MAST. ABS STAPLE LEAK
6) FHA HALL BATH ABS VENT
7) REMOVE STAPLES BEHIND HOME RUNS
8) H2.5 TRUSS ABOVE BALCONY
9) MOVE PEX FROM KITCHEN
10) BANG CONDENSATE
11) COMPLETE MESH AT COMBUSTION/RELIEF VENTS