Permit: T05CM01648

Parcel: 10120040D

Inspection Status: Approved

Inspection History: SITE - SEWER

Date Description Inspector Results Comments
01/06/2006 SITE - SEWER Approved IVRS - Inspection :*BLDG SEWER FROM 2 WAY C.O TWO PLACES-THROUGH INTERCEPTOR AND INTO OK
OK TO COVER
ROOF DRAINS OK-ABS DWV THRU ROOF OK-OK TO INSULATE HOT
12/28/2005 SITE - SEWER Partial Approval IVRS - Inspection :*SOME OF THE PIPING BETWEEN BLDG AND INTERCEPTOR COVERD W/O INSPECTION.
INTERCEPTOR NOT VENTED PER PLAN
VENT SIZE MAY NOT BE REDUCED
VENT TO BE WITHIN 10' OFF INTERCEPTOR
USE DRAINAGE FITTINGS
INVERT OF VENT TO BE ABOVE DRAINAGE CENTERLINE