Permit: T05CM01632

Parcel: 136141220

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM01632

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/25/2005 FRAMING Approved IVRS - Inspection :*
07/21/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEARWALL BLOCKING PANELS REQUIRE PD'S AT 3" ON CENTER
2) BLOCKING PANELS NOT NAILED PER 6/SD2
3) RED HEAD ANCHOR BOLTS LOOSE
4) GARAGE P-1 SHEARWALL REQUIRES ANCHOR BOLTS AT 32" ON CENTER S-1 NOTE "B"
5) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE
6) ANCHOR W/C FLOOR FLANGE
7) PROVIDE POST UNDER EAST END OF MICRO ? TRUSS TO FOUNDATION
8) OK TO INSULATE